Watts IntelliFlow A2C-M1 Manual Del Usuario página 7

Válvula de cierre automático para lavadora
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Front Panel Status Indicators
GREEN LED: ON: Unit powered
YELLOW LED: ON: Water supply Open.
OFF: Water Supply Closed.
Sensor Plug
RED LED: ON: Leak Sensed.
BLINKING: Unit Timed Out –
FAINT BLINK: (3-5 seconds) –
What is Surge Protection?
In many locations, changes in the AC voltage supply to the home by the
electrical utility company can occur. Both lower voltage (brownouts) and
high voltage (surges) can occur. Lightning strikes can also cause high
voltage spikes to occur.
All electronic equipment is designed to operate properly within
a voltage range. However, high voltage surges or spikes can
damage sensitive circuitry within electronic equipment.
Surge protectors prevent voltage spikes from reaching
electronic equipment.
This lamp is illuminated whenever the IntelliFlow
a powered wall outlet.
This lamp is illuminated whenever the IntelliFlow
current flow (the washing machine is turned on).
It is off when the washing machine is turned off.
NOTICE
Some washing machine models include circuitry that
causes a slight current draw at all times. These models when
connected to the IntelliFlow
energized continuously (Yellow LED: ON).
This lamp is illuminated when the leak sensor is installed and
water has been detected at the sensor. The water supply to the
washing machine hoses are interrupted when a leak is detected.
This lamp blinks whenever the internal timing circuit has timed
out and has shut off the water supply to the washing machine
hoses. Turning the washing machine Off then On will reset the
timing circuit.
This condition indicates the leak sensor is unplugged. To provide
the maximum level of protection, it is recommended that the
leak sensor be installed at all times.
What is Ground Fault Protection?
In many locations, an electrical differential between an electrical ground
and a water pipe ground can exist. A person touching both grounds
could receive a shock that may cause injury or death. A ground fault
interrupter circuit (GFI) detects the differential and removes electrical
power before injury can occur.
The IntelliFlow
®
does not cause or change the electrical dif-
ferential that exists.
7
is plugged into
®
®
senses
can cause the water supply to be
®
Tabla de contenido
loading

Este manual también es adecuado para:

Intelliflow a2c-wb-m1

Tabla de contenido