ELECTRIC PRUNING SHEARS
K. Screw the M5 hexagon socket
countersunk head counterclockwise
as shown.
15.4. TOOL CALIBRATION
If a replacement motor or drive plate is required, the pruners need to be
recalibrated.
Follow next steps to perform the calibration:
Remove the upper and lower blades.
Insert the battery.
Hold down the trigger and keep it pressed. Press the POWER switch again.
Maintain the trigger pressed for more than 10 s.
Release the trigger when you hear the motor turning.
The electric motor rotates during calibration. When the motor stops turning
the calibration is complete.
Reassemble the blades as indicated in chapter 15.3.
K
L. Reduce the friction between the
two plans of the blades by adding
grease through the hole of the
plastic cap as shown in the figure.