9.3. DESCRIPTION OF THE TERMINALS
]
AP1
Hall button terminals for pedestrian electric lock (OP4)
]
AP2
Hall button terminals for garage gate lock (OP5)
}
C
Garage gate opener operation dry contact (OP6) - maximum switch 1 A @ 30 V
NO
}
L
BUS line
L
}
SE2
Pedestrian electric lock operation (OP1) - maximum switch 12 V~ 15 VA
SE1
9.4. PEDESTRIAN GATE ELECTRIC LOCK ACTIVATION TIME SETTING
The pedestrian gate electric lock activation time can be adjusted using the dip switches present in the
calling station:
9.5. CAMERA LED ON / OFF ADJUSTMENT
The position of the jumper on the inside of the device can be used to select the turning ON or OFF the
camera LED.
During installation phases, the leds of the TV camera can be disabled. This operation must
be carried out only if the call station is installed in an area where suffi cient lighting is guaranteed during the
day and night.
To de-activate the leds of the TV camera, operate on the jumper indicated in the fi gure.
DS1722-125
OFF
ON (default)