The VSSP 2.0 is a diagnostics device for start-stop
batteries and conventional batteries. With the VSSP 2.0,
for batteries installed in vehicles you can
check the state of charge and the state of health,
test the starter and the alternator,
check the control units (ECUs) that are relevant
for the  start-stop system, read out and delete
the appropriate error codes.
To do this connect the VSSP 2.0 via connection (7)
to the OBD interface of the vehicle and to the vehicle
battery via the connection  (4) with the current clamp
or the connection  (3) with alligator clamps. Both the
connectors of the measurement cable as well as the two
power measurement connections (3, 4) are marked with
white arrows that facilitate correct connection.
The device can communicate with VARTA VSSP server
via a WiFi connection. The prerequisites are a local
computer with Internet access and a WLAN router.
In addition registration must have been executed with
the password and user ID that was sent together with
the license package.
The test results will be shown directly on the VSSP 2.0
and transmitted to the Start-Stop website in the form
of a report (www.varta-startstop.com) and can
be printed.
If the vehicle battery must be replaced, the VSSP 2.0
displays the recommended VARTA battery and guides
you step-by-step through the replacement procedure via
the menu.
After you have replaced the battery, use the integrated
2D data matrix scanner (11) to read in the VARTA code.
Two lights (10, 12) integrated on the rear of the device
facilitate readout of the code.
With the VSSP 2.0 you also check the state of charge
of stored new and used batteries. To do this, connect
the VSSP 2.0 to the battery via the alligator clamps.
Device description
VSSP 2.0