Heating Slim Receiver RTS 2kW / Heating Slim Receiver RTS 2kW Plug
5.2. Creating multiple or group controls
5.2.1. Group control
Group control: an RTS control point controls several Heating Slim Receiver RTS 2kW units.
1)
Cut the power supply to the Heating Slim Receiver
RTS 2kW units (h, i and j) to be controlled by a single
control point.
2)
Switch on the power supply to the rst Heating Slim
Receiver RTS 2kW (h) to be linked to the control
point.
3)
Simultaneously press the Up/Down buttons on the
RTS control point: the heating lamp comes on then
goes out.
4)
Press the PROG button on the RTS control point: the
heating lamp will come on then go out again to indicate
that the RTS control point has been programmed into
the Heating Slim Receiver RTS 2kW.
5)
Switch off the power supply to the newly linked
Heating Slim Receiver RTS 2kW before adding the
next Heating Slim Receiver RTS 2kW.
6)
Switch on the power supply to another Heating Slim
Receiver RTS 2kW to be linked and repeat steps 3),
4) and 5).
-
Repeat the procedure for each of the other Heating Slim Receiver RTS units to be controlled with this
RTS 2kW control point.
5.2.2. Multiple control
Multiple control: a Heating Slim Receiver RTS 2kW is controlled by several RTS control points.
A maximum of 12 control points may be programmed into a Heating Slim Receiver RTS 2kW.
1)
Press the PROG button on the programmed control
point (k) until the heating lamp comes on then goes
out: the Heating Slim Receiver RTS 2kW will be in
programming mode for 2 minutes.
2)
Brie y press the PROG button on the RTS control
point (l) to be added: the heating lamp comes on then
goes out; the RTS control point has been added/
removed.
-
Repeat these two steps to add each RTS control point.
6. Using the heating ramp
With an RTS control point
To switch on the heating ramp:
-
Press the Up button.
To switch off the heating ramp:
-
Press the Down button.
7. Tips and recommendations
7.1. Questions on the Heating Slim Receiver RTS 2kW?
Observations
Pressing a button on the
control point has no effect
on the heating ramp
4
Possible causes
One or more heating lamps is blown.
1
OFF
h
2
ON
h
4
PROG.
h
1
2
PROG.
k
Solutions
Replace the heating lamp(s).
Copyright © 2010 Somfy SAS. All rights reserved.
i
j
3
h
h
PROG.
l
2 min.