THE INSTALLATION SPACE

*Finished Width
Electrical
84 1/2" max
Area
83 1/2" min
Finished
Opening
24"
5"
Water Supply
3 1/2"
*The finished cutout width must be:
41-1/2" for 42" models
Water And Electrical Locations
The opening must be prepared with the electrical and
water supply located as shown.
The cutout depth must be 24"
The refrigerator will project forward, slightly beyond
adjacent cabinets, depending on your installation.
Additional Specifications
• A 120 volt, 60Hz, 15 or 20 amp power supply is
required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be
located on rear wall as shown.
Note: GFI (ground fault interrupter) is not
recommended.
• Water line can enter the opening through the floor
or rear wall. The water line installed should be 1/4"
O.D. copper tubing or GE SmartConnect™ tubing
between the cold water line and water connection
location. The line should be long enough to extend
to the front of the refrigerator. Installation of an
easily accessible shutoff valve in the water line is
required.
Design Guide
3"
7"
5"
74"
From Floor
to Bottom
of Electrical
5"
3 1/2"

DIMENSIONS AND CLEARANCES

25-3/8" Case Depth
41"
Case Width
*81-3/4"
at Rear
42" Frame-to-Frame
Depth Including
Handles 26-7/8"
Refrigerator Clearances
These refrigerators are equipped with a 2-position
door stop. The factory set 130° door swing can be
adjusted to 90° if clearance to adjacent cabinets or
walls is restricted.
130° Door Swing
A
Models
A
42"
12-3/16"
Allow minimum clearances for Freezer door
(Dimension A) and Fresh Food door (Dimension B) for
a full 130° door swing and to allow for drawer
removal.
Four inch (4") minimum clearance is required when
door swing is adjusted to 90°. If the 90° door stop
position is used, drawer access is maintained, but
drawer removal is restricted.
See illustrations, pages 5 and 6, to determine door
swing interaction with adjacent cabinets or
countertops.
4
*Shipping height
The front height
may be adjusted
from 83-1/2" to 84-1/2"
by adjusting front and
rear leveling legs a
maximum of 1".
*84" From
Floor to
Top Frame
90° Door Swing
B
D
B
C
D
16"
24"
4"
23-7/8"
Behind
Frame
C