WARNING
Failure to follow manufacturer' s instructions
could result in serious injury or death. User must
follow instructions included for complete system.
- Attach anchor with eight (8) #12 screws (2-1/2"
min. length) or other Miller approved fasteners
through holes provided. Position so that fasteners
attach to a support structure. Use all holes.
- Support structure must be capable of supporting
a 5,000 lb. static load or provide a 2:1 safety
factor.
- Connection to anchor must only be made with a
locking carabiner, a locking snap hook or other
Miller Fall Protection approved connector or
connecting device.
- Fall protection system must include a shock
absorber which limits forces to 900 lbs. or less.
- This is not a permanent anchor point. Refer to
the instructions included for reuse of this bracket
and limitations.
Questions? Call 800-873-5242
LB354 Rev. C
WARNING:
Failure to follow manufacturers instructions could result
in serious or fatal injury. Attach anchor with (6) six 16d nails or (3)
three 1/4 x 2-1/2" or longer lag screws. Position so that fasteners
attach to a support structure.
Compliance: OSHA 1926.502
Capacity: 310 lbs. (140.6 kg)
Heavy Duty Multiple Use Roof Anchor
Model: RA30-1
WARNING
Failure to follow manufacturers instructions
could result in serious or fatal injury. Support
structure must be capable of supporting a
5,000 lb. (22 kN) static load or provide a
2:1 safety factor.
BEFORE USING
Inspect before each use for any signs of
damage, wear or malfunctioning components.
RA35-1
Material: Steel
Questions? Call: 800-873-5242
INSTALLATION
Attach anchor with (12) twelve 16d nails or
(6) six 1/4 x 2-1/2" or longer lag screws.
Position so that fasteners attach to a
support structure.
ROOF PEAK
TRUSS/
RAFTER
SHEATHING
Compliance: OSHA 1926.502
Capacity: 310 lb. (140.6 kg)
Material: Steel, Copper, Nylon
Questions? Call Miller Fall Protection 1-800-873-5242
WARNING
Failure to follow manufacturer's instructions
could result in serious injury or death. User
must follow instructions included for complete
system.
- Attach anchor with eight (8) #12 screws
(2-1/2" min. length) through holes provided.
Position so that fasteners attach to a support
structure. Use all holes.
- Support structure must be capable of
supporting a 5,000 lb. static load or provide a
2:1 safety factor.
- Connection to anchor must only be made with
a locking carabiner. DO NOT use snap hooks.
- Fall protection system must include a shock
absorber which limits forces to 900 lbs. or less.
- This is not a permanent anchor point. Refer to
the instructions included for reuse of this
bracket and limitations.
LB424 Rev. C
Questions? Call 800-873-5242
LB205 Rev. B
LAG SCREWS
NAILS
LB420 REV. B