Outdoor Unit
Installation way of
ventilation clamp
Upper Duct Plate
Fabric Duct
5. Secure the ceiling assembly frame to the roof top air conditioner with the mounting bolts(see Figure 5).You
must start (thread) themounting bolts by hand to avoid cross-threading. DO NOT START THE MOUNT-
ING BOLTS WITH AN AIR GUN. The mounting bolts should be tightened, process is completed when the
basepan gasket has been evenly compressed
6. Set the fabric air duct into the duct opening ofinstallation plate sub-assy and cut off four corner of fabric air
duct. Because the thickness of vehicle top is different, the distance between the opening and the installa-
tion plate sub-assy is shown in figure 6.
7. Fasten each side of the fabric duct with fitting the bottom duct plate to the ceiling assembly frame with 4
screws (see Figure 6).Trim any excess fabric that may extend beyond edge of bottom duct plate.
39
Indoor Unit
This should
be assembled