FES-200 W3
9.1 Inspection intervals
NOTICE
• The specified maintenance intervals are guidance values and refer to single-shift operation.
• We recommend recording the inspections. The date of the inspection, the detected defects and the
Check the following:
Every day by the user
Visual inspection:
Fume extraction system or parts of system
damaged?
Visual inspection:
Cable connections damaged?
Filling level of the dust collecting drawer
5.1 Emptying the dust collecting
drawer on page EN-13
Tab. 7
Inspection intervals
name of the inspector must be recorded.
Every month by qualified personnel
Visual inspection:
Filter untight? (trails of dust or deposits on the air
outlets)
Visual inspection:
Function of the minimum air volume flow control
guaranteed?
Seal the air inlet. As soon as the value on the
manometer indicator increases, an acoustic
signal sounds.
9 Maintenance and cleaning
Every year by qualified
personnel
Visual inspection:
Dust in the turbine area, remove dust
using an industrial vacuum cleaner or a
damp disposable cloth.
Visual inspection of the filter cartridge
Check the tightness
Measure the volume flow
Measure the vacuum
Measure the current consumption
EN - 23