Notes
Only use splitters without diodes (EBC 110 or EBC 114). The required diode
protection is provided by outlets from the ESU series.
By defi nition the system is designed so that single-cable units are supplied with
14 V DC. The power supply is briefl y switched to 18 V DC if control signals si-
milar to DiSEqC™have to be transmitted. Continuous application of 18 V would
block the system.
Sockets of the ESR series are specifi ed in the data sheet from 47 MHz. The
very small directional losses in the range 5-47 MHz used in the K-speed mo-
dems in this case, is an advantage. They can therefore be used without any
problems.
It is recommended to assign the outlets with the shorter cable lengths the higher
frequencies.
The multi-switch (with integrated modem) EXI 3591 is ideally used in combinati-
on with the single modem EXI 01.The subscriber of this multi-switch is specially
adapted to terrestrial and offers the optimum conditions for the data rates of the
modem to EXI 3591 but also between multiple EXI 01s. An integrated high pass
fi lter for terrestrial input prevents unwanted distribution of your network data on
a connected antenna.
To achieve optimum performance, make sure when your entire distribution that
supports the frequency range 5-68 MHz.
The receivers that are connected must be designed for single-cable operation
conforming to EN 50494. In order to use userband 9, the receiver must also
support the single-cable standard SCD2 as per prTS 50607.
Startup of the modem
The integrated modem in the multi-switch EXI 3591 and the Kathrein modem EXI 01 are
secured from the factory with a network key. For easy operation of these two modems must
be connected to a coaxial cable to the socket
such as routers and receivers are connected using the supplied Ethernet cable to the pro-
vided RJ-45 jack. The LEDs „Power" and „Coax / Link" light. The data link is established.
Up to 64 modems may be connected to each other.
Additional security:
"Ensure" that in a coaxial distribution system all the modems connected are Kathrein. If you
want to build a private network with your own modems, proceed as follows:
. Connected to the network devices
5 / 12