Terminal board connections
7
CMN common for all inputs and outputs
8
ELS electric lock output (fed continuously) 12 Vdc - 15 W.
9-10 LC-CH2 potential free contact for the activation of the courtesy light
(separate power supply Vmax = 30 Vac/dc: Imax = 1A) or the second
11
CMN common for all inputs and outputs
12
LP 24 Vdc 25 W output for warning lights
intermittent activation (50%), 12,5 W continuous activation
13
LS 24 Vdc 3 W output for an indicator light
14
CMN common for all inputs and outputs
15
30 Vdc controlled output, powering external loads
16
CMN common for all inputs and outputs
17
30 Vdc output, powering external loads
18
CMN common for all inputs and outputs.
19
TA (NO contact) opening button input
20
TC (NO contact) closing button input
21
TAL (NO contact) limited opening button input
22
TD (NO contact) dynamic button input
23
CMN common for all inputs and outputs
24
TB (NC contact) stop button input (The opening of this contact inter-
rupts the cycle until a new movement command is given).
25
FTCS (NC contact) Safety and control devices in input. (stop photo-
electric cells). The opening of this contact will block all movement, until
the obstruction has been removed and the pause time has elapsed, due
to the safety device cutting in, the door will then continue moving in the
closing direction (only with automatic reclosing enabled).
26
FTCI (NC contact) Safety and control devices in input (photocells invert
the travel direction when an obstruction is detected). Opening this contact
will provoke a travel direction inversion during closure due to the cutting
in of the safety device.
27
EMRG2 (NO) emergency manoeuvre input 2
28
EMRG1 (NO) emergency manoeuvre input 1
29
CMN common for the emergency buttons
30
Inner conductor for radio receiver antenna (if an external antenna is
fitted use a coaxial type cable RG58 with an impedance of 50 ).
10
J1
F3
L3
J2
10
Collegamento motori/encoder a 4 fili
Connecting motor/4-wire encoder
Branchement moteur/encodeur à 4 fils
Anschluss der Motor/Encoder mit 4 Drähten
Conexionado motores/encoder de 4 conductores
COLORE
CABLAGGI
Bl
Blu
Gr
Verde
Gy
Grigio
Yw
Giallo
KABELFARBEN
Bl
Blau
Gr
Grün
Gy
Grau
Yw
Gelb
ENCODER 1
M1
Bl
Gr
1
2
3
4
B1
via radio
CSER Serial connection (only for diagnostics)
D1
Six-segment LED display
DS1
Selection dip-switch
F1
10A blade fuse
(5)
(motor power protection)
F2
10A blade fuse
(5)
(motor protection during battery operation)
F3
4A
blade fuse
(5)
(24V circuit protection)
F4
4A
blade fuse
(5)
(24V circuit protection during battery operation)
F5
4A
blade fuse
(5)
(electric lock protection)
J1
Battery connection
J5
(1)
(1)
4A
F2
F4
L2
L1
F1
COLOUR CODE COLORATION
CODE
DES CÂBLAGES
Blue
Bleu
Green
Vert
Grey
Gris
Yellow
Jaune
COLORACIÓN
CABLEADOS
Azul
Verde
Gris
F5
Amarillo
M2
ENCODER 2
Gy
Yw
Bl
Gr
Gy
Yw
5
6
1
2
3
4
5
6
31
Outer conductor for radio receiver antenna
Note
(1)
The total of the 2 external device outputs must not exceed 10 W.
ALL UNUSED NC CONTACTS MUST BE JUMPED and consequently the
security device test must also be deactivated (FTCI , FTCS - Dip 7 and Dip
OFF
and receiver parts of the security devices must be connected to the binding
CTRL 30 Vdc
delay between the command transmission and movement of the gate/s.
Switch on the power and make sure that the indicator LEDs are in the fol-
lowing condition.
- L1 Power on
- L2 Battery charging
- L3 Wrong battery connection
- L4 Transmitter code programming indicator
- L5
- L6
- L7
- L8
- L9
- L10
- L11
Note
:
(2)
Note
:
(3)
Note
: Check that the activation of the safety devices switches the cor-
(4)
responding LEDs off.
If the green power on LED "L1" doesn't light up check the condition of the
fuses and the power cable connection at the transformer primary.
If one or more of the safety LEDs do not light up check the contacts of the
relative security devices and check that the unused safety device contacts
have been bridged.
R1
MM
L5
J3
J4
L6
L7
DS1
P2
TD
RA
L4
PLP
LP
LS
P3
FTCI
TFTI
TFTS
SAP
ELS
LC/CH2
7
8
9
10
11
12
13
14
15
16
J2
Transformer secondary protection
J3
Enable transmitter memorisation via radio
J4
Radio channel selection
J5
Binding posts 9, 10 selection (courtesy light/CH2 via radio)
MM
Transmitter code memory module
P1
Programming button (PROG)
P2
Transmitter code memorization button (MEMO)
P3
Transmitter code cancellation button (DEL)
R1
Radio frequency module, 433 MHz for S449 transmitters
Note
(5)
: These are automotive type blade fuses (max. voltage 58 V)
17
FTCI, FTCS test both the transmission
TB
FTCS
TA
TC
TAL
TD/CH1
ON
ON
CS 1218 DC0355
B1
L8
L10
D1
L9
L11
CSER
J5
1 2
1 2
3
3
Pos.1
Pos.2
CMN
EMRG 1
EMRG 2
17
18