RIB PRESIDENT Serie Manual De Instrucciones página 23

Barrera irreversible para control de trafico vehicular
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Parts to install meeting the EN 12453 standard
COMMAND TYPE
Skilled persons
(out of a public area*)
with manned operation
A
with visible impulses
C
(e.g. sensor)
with not visible impulses
C
(e.g. transmitter)
automatic
C and D
* a typical example are those shutters which do not have access to any public way.
A: Command button with manned operation (that is, operating as long as activated), like code
ACG2013.
B: Key selector with manned operation, like code ACG1010.
C: Built-in Encoder (operating as thrust limitation device, within the limits indicated by
specification EN12453 - Appendix A).
D: Built-in Encoder (operating as presence detector).
A - ELECTRIC CONNECTION
B - SW1 - MICROSWITHCES FOR THE GEARCASE SETTING
DIP 1 - MOTOR DECELERATION CALIBRATION (ON) (POINT C)
DIP 2 - PROGRAMMING TIMES (ON)
OPERATING MICROSWITCH
DIP 3 - Waiting time before the automatic closing (ON) (max 5 min.)
DIP 4 - Step by step radio receiver (OFF) - automatic (ON)
DIP 5 - Single impulse control (K BUTT) step by step (OFF) - automatic (ON)
DIP 6 - Normal working (OFF) – Park working (ON)
DIP 7 - Encoder exclusion as security (OFF - encoder on / ON - encoder off)
DIP 8 - Function of the key OPENING 2 check in Park mode.
ON - the key OPENING 2 is always authorized,
OFF- the key OPENING 2 is authorized only if there is no presence on INPARK.
DIP 9 - Working after black-out WITH batteries.
ON - The rod opens and stops in the opening position with the exclusion of all
USE OF THE SHUTTER
Skilled persons
Unrestricted use
(public area)
B
-
C
C and D
C and D
C and D
C and D
C and D
controls. When the network input is back, the bar closes resetting all controls
OFF - The bar carries out the normal working until the battery is exhausted.
DIP 10 - Working after black-out WITHOUT batteries.
ON - The bar closes
OFF - The bar stops in the point where the black-out happened.
S1
PROG. Key for the programming.
TERMINAL BOARD J1
SEC.TRANSF.
Connection for secondary transformer (carried out in the factory).
CONNECTOR J2
MOTOR Connection MOTOR and ENCODER (carried out in the factory).
23
PARK 24V code BC07061
G
B
Tabla de contenido
loading

Este manual también es adecuado para:

President 3mPresident 4mAa50075bAa50076bAa50077bAa50078b ... Mostrar todo

Tabla de contenido