Electrical safety

The Premium spas are safe products, manufactured in com EN
60335-1, EN 60335-2-60, EN 12764 and tested during produc-
tion to ensure user safety.
I Installation must be carried out by qualified and authorized
personnel, in compliance with current national provisions.
It is the responsibility of the installer to select materi-
als based on their intended use, to carry out work
properly, to check the condition of the system that the
unit will be connected to and that it ensures safety of
use also concerning maintenance work and the possi-
bility to examine the system.
I The Premium spas are class "I" appliances and therefore they
must be permanently connected, without any intermediate
connections, to the electrical system and to the protection sys-
tem (earth system).
The electrical system of the building must be provided
with a 0.03A differential switch and with an efficient
protection (earth) circuit.
Check for proper operation of the differential switch
by pressing the TEST button, which should trip.
Parts incorporating electrical components, except
remote control devices, must be located or fixed so
that they cannot fall into the spa.
Live components and equipment must be out of
reach of individuals in the spa.
I For electrical connections, the installation of a multiple-pole
section switch is compulsory (
in a place that complies with safety regulations and, in any case,
which cannot be reached by those using the spa.
It is mandatory to comply with this instruction. Any other proce-
dure is prohibited.
I The disconnection devices must be installed in the power sup-
ply network according to the installation instructions.
I The installation of electrical devices and equipment (sockets,
switches, etc.) near the spa must be in compliance with legal
standards and regulations in the country where the spa is
installed.
I For the equipotential connection as required by specific
national standards, the installer must use the terminal provided
(standard EN 60335.2.60)in the electrical box (
marked with the symbol
In particular, an equipotential condition must be established for
all metallic masses surrounding the spa, for example water and
gas pipes, metallic platforms, and so on.
i
5-6-7). It must be positioned
i
5-6-7), and
.