When mounting the detector on ceiling
Please keep the detector at least 4m (B)
away from the wall of wooden, glass or
brick material which thickness is less than
30cm (A) or 1m (B) away from the wall
which thickness is over 30cm (A). Also,
users can adjust Meter knob to decrease
the sensitivity and coverage, which can
avoid false triggering when people
passing through outside the wall.
The water-flow in waterpipe would be possible to trigger the HF detector. It is
recommended to keep the detector away from the waterpipe as the following
guidelines to avoid nuisance triggering.
Waterpipe
(Dia. Φ 10cm)
Waterpipe
(Dia. Φ 10cm)
Function
The function of R terminal
Terminal of R and push button (N.O.) can be series connected to control
load's on / off manually. (case 1: on → off; case 2: off → on). While pressing
push button ( ≤ 1sec):
Please note, this function is invalid when the lighting (detector) is in the On
8hrs & Off 8hrs conditions set by IR remote control.
www.grupotemper.com
<
2m
<
<
1m
<
FIG.4
Highbay presence detector
B
<
B 4m (at A < 30cm)
<
<
B 1m (at A 30cm)
A
FIG.3
<
2m
Waterpipe
<
(Dia. Φ 10cm)
<
1m
Waterpipe
(Dia. Φ 10cm)
<
Instructions manual |
KDP5
Detector
25