CE CONTROL PANEL WITH TIMER - In this IP55 control panel there is a reverse
switch, an automatic control device (timer) and a black starting button which
must be pressed before starting the pump every time the pump is connected to the
supply source and after every possible
device, use the MAN/AUT switch. The mode MAN (manual) excludes the timer; the
pump will be directly controlled by the reverse switch. The AUT(automatic)
mode uses the timer and allows the pump to run without user intervention. The
selection is done by using the graduated knob WORK (LAVORO) and PAUSE (PAUSA).
Using the WORK knob it's possible to set the run time (12 positions; LIV1 and
LIV2 types from 2 to 24 min), while with the PAUSE knob it's possible to set the
pause time (12 positions; LIV1 type from 10 to 120 min, LIV2 type from 1 to 12
hours). The work/pause phases are shown by the corresponding pilot light.
After fixing the work/pause cycles (which can be modified even during the
working phase), action the pump using the reverse switch.
3.3 PUMPS WITH VARIATOR
The rotation speed is regulated according to the needs by the control wheel
placed on the variator. The clock arrows inside the control
reference speed (see table).
ATTENTION! - The control drive of the variator must NOT be
moved when the electric motor is not running.
ATTENTION! - Before the first use, replace the red plug with
the air valve (A).
0
START
1
2
LAVORO
22
current drop. To choose the control
POMPA
MAN - 0 - AUT
PAUSA
wheel show the