CE CONTROL PANEL
black start button (START), that has to be pressed before you want to start the
pump, each time you connect the control panel to the feeding source and in case
of voltage drop.
CE CONTROL PANEL WITH ADDITIONAL SHUNT
reverse switch and a starting black button (START), which must always be
pressed before starting the pump every time the panel is connected to the
feeding source and after every possible current drop. The panel also has an
additional 24V shunt (normally closed contact) which connects a temperature
sensor (standard mounting) and allows the connection of other devices by
request (pressure switch, level sensor, remote control, etc.).
1 speed
lowest
speed
highest
speed
TEMPERATURE SENSOR (DRY RUNNING PROTECTION) - The dry running protection,
connectetd directly to the pump body by a sensor (1), stops the impeller
running when the internal temperature is higher than 50 °C, in order to avoid
burning or deformation. This protection is not suitable for the transfer of
liquids at a temperature higher than 45 °C.
ATTENTION! - The dry running protection device does not
interrupt
temperature is lower than 50 °C the pump automatically starts
working again.
- In the IP55 control panel, there is a rotating switch and a
1 speed + Starting
2 speed
lowest
speed
highest
speed
the
passage
- In this IP 55 control panel there is a
(CE control panel only)
of
electric
21
starting button
current;
when
the