Technical Data; Troubleshooting - Stiebel Eltron MINI 2 Operación E Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

INSTALLATION

TECHNICAL DATA

11. Technical data
Model
Item number
Phase
Voltage
Wattage
Max. amp, load
Min. required
circuit breaker size
Required wire size
AWG COPPER
Min. water flow to
activate unit
Recommended
inlet temp. range
Nominal water
volume
Working pressure,
max.
Tested to pressure
Weight
Dimensions
Height
inch (mm)
Depth
inch (mm)
Width
inch (mm)
Water connections
Heating System
* Note: Mini 2 is internally restricted to 0.32 GPM
-Tankless water heaters are considered a non-continuous load
-Conductors should be sized to maintain a voltage drop of less than 3 % under load
-For use with cold water supply only

12. Troubleshooting

E
WWW.STIEBEL-ELTRON-USA.COM
Mini 2
*
231045
1
V
115 - 125
kW
1.8
A
16
A
20
12
GPM
0.21
(
l/min)
(0.8)
°F (°C)
GAL (l)
PSI (bar)
PSI (bar)
lbs. (kg)
Symptom
No hot water
despite fully
opened hot
water
faucet.
Mini 2.5
Mini 3
232098
220816
1
1
115 - 125
115 - 125
2.4
3.0
21
25
30
30
10
10
0.40
0.40
(1.5)
(1.5)
Possible cause
No electrical
power.
The activation fl ow rate needed to
turn on the heating element has not
been reached.
Safety cut out tripped
MINI™ SERIES TANKLESS ELECTRIC WATER HEATERS |
Mini 3.5
Mini 4
232099
222039
1
1
115 - 125
208
240
3.5
2.9
3.5
31 13.8 15.2
22.4 24.7
40
20
20
10
12
12
0.40
0.40
(1.5)
(1.5)
41-77 (5-25)
for 3/8" O.D. flex connector
Nichrome bare-wire
Solution
Check the circuit breaker and
check voltage at the wiring
Clean fi lter
screen.
– turn circuit breakers off
– open Hot Valve to release pres-
sure from the unit
– reset saftey pressure cut out
– turn circuit breakers on
Mini 6
220817
1
208
240
4.7
5.7
30
30
10
10
0.77
(2.9)
0.026 (0.1)
150 (10)
300 (20)
3.44 (1.56)
1
6
/
(165)
2
3
1
/
(82)
4
1
7
/
(190)
2
block.