MAINTENANCE AND TROUBLESHOOTING
DANGER - ELECTRIC SHOCK RISK
Before doing any operation, make sure machine is disconnectedfromelectricpowersupply.
Periodical maintenance should be performed according to the content of sand in water. In ordinary conditions, SCM 4 Plus®, SCM 4
HF and SA 6 pumps do not require servicing.
•
To prevent possible failure, it is
advisable to periodically control the
flow rate and current absorption
•
A fall below 50% in the flow rate,
as compared to the rated value,
indicates that the pump is worn
•
Similarly, an increase of the current
absorption above 5% indicates the
presence of abnormal mechanical
failures in the pump and/or motors
14
•
In many cases, it is necessary to
replace the worn parts, like impellers,
O-rings and bearings
•
If the content of sand in pumped
water is high, it is advisable to inspect
the pump for the first time after about
one thousand operating hours
•
If the pump is left idle in the well for
long intervals of time, it is advisable
to start it and allow it to run for a
short time every 2-3 months
•
Always make sure that the unit is
completely submersed