CHAPTER 8
MAINTENANCE AND TROUBLESHOOTING
DANGER - ELECTRIC SHOCK RISK
Before doing any operation, make sure machine is disconnectedfromelectricpowersupply.
Periodical maintenance should be performed according to the content of sand in water. In ordinary conditions, SCM 4 Plus®, SCM 4 HF
and SA 6 pumps do not require servicing.
•
To prevent possible failure, it is
advisable to periodically control the
flow rate and current absorption
•
A fall below 50% in the flow rate, as
compared to the rated value, indicates
that the pump is worn
•
Similarly, an increase of the current
absorption above 5% indicates the
presence of abnormal mechanical
failures in the pump and/or motors
14
•
In many cases, it is necessary to
replace the worn parts, like impellers,
O-rings and bearings
•
If the content of sand in pumped water
is high, it is advisable to inspect the
pump for the first time after about one
thousand operating hours
•
If the pump is left idle in the well for
long intervals of time, it is advisable
to start it and allow it to run for a short
time every 2-3 months
•
Always make sure that the unit is
completely submersed