Xse Transmitter - SOMFY Home Motion ROLLIXO RTS Manual De Instalación

Ocultar thumbs Ver también para Home Motion ROLLIXO RTS:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Rollixo RTS
Diagnostics
Consequences
resistive
wired safety
edge
Actions
Diagnostics
Consequences
Actions
Diagnostics
Consequences
radio safety
Actions
edge
Diagnostics
Consequences
Actions
Diagnostics
Consequences
Actions
14
indicator light status
Wired resistive safety edge failure
Opening ok
Closing by pressing and holding down
the button within sight of the door
- Check the type of safety edge connected
(wired resistive safety edge, dipswitch
no.4 set to ON); if the connected wired
safety edge is optical, move dipswitch
no.4 to OFF.
- Check the safety edge wiring (see
section 8.3).
- Check that no radio safety edge
transmitter is stored in the receiver. If a
radio safety edge transmitter is stored in
the receiver, clear it (see section 13).
Radio safety edge failure
Opening ok
Closing by pressing and holding down
the button within sight of the door
Request movement again and if the
problem persists:
- See radio safety edge transmitters for
diagnostics (see sections 15.2, 15.3 and
15.4).
- Repeat the safety edge transmitter
programming procedure on the receiver
(see section 11).
Radio interference on the safety edge
transmitter
Opening and stopping ok
Closing by pressing and holding down
the button within sight of the door: the
closing movement will automatically
resume when the radio interference
disappears.
If a powerful radio system is present on
the site (infrared detector, TV transmitter,
etc.) and is transmitting on the same
frequency, the receiver will wait for the
transmission to end to before controlling
the door again.
Upper magnet absent if ESE edge
transmitter installed
Opening ok
Closing by pressing and holding down
the button within sight of the door
Check that the magnet is present and
install if not (see section 6.1).
End of life of the safety edge transmitter
batteries
Opening ok
Closing by pressing and holding down
the button within sight of the door
Safety edge transmitter low battery
indication.
If the fault persists, replace the safety
edge transmitter batteries.
Prog
Diagnostics
Consequences
Actions
Diagnostics
Consequences
Actions
Photoelectric
cells
Diagnostics
Consequences
Actions
Diagnostics
Consequences
Actions
radio
Diagnostics

15.2 Xse transmitter

> Problem on Xse transmitter
LeD1 and LeD2:
Stage 1: CHECK THE BATTERY
Remove the battery then press a button (PROG or MODE) to discharge
the residual energy from the electronics. Refit the battery and wait for the
automatic battery test to be completed (an orange light flashes to signal the
test is under way - it may last up to 2 minutes).
- If LED1 and LED2 light up red for 5 seconds, replace the battery and repeat
the operations above.
- If LED1 and LED2 light up green for 5 seconds, skip to step 2.
Stage 2: CHECK THE OPERATION OF THE SAFETY EDGE
Press and hold the MODE button for 3 seconds to launch safety edge
detection.
- If LED2 lights up green then the safety edge and transmitter are operating
correctly. Squeeze the safety edge and check that LED2 lights up red.
- If not, go to step 3.
indicator light status
Obstacle detection
Remove the obstacle by automatic partial
opening
Check that no obstacle is causing the
safety edge to detect.
If the floor is being detected, check that
there is a magnet fitted at the down point
and install one if necessary or rectify the
ground to make it smooth and even.
Cell fault
Opening ok
Closing by pressing and holding down
the button within sight of the door
If no cells are installed, check that the
connector (terminals 18 and 19) is
bridged.
If cells are installed:
- Check that no obstacle is cutting across
the cell beam
- - Check the position of dipswitch no.2
according to the type of cell (see
section 8.2).
- Check the cell wiring (see section 8.3).
Bridged cell connector
Opening ok
Closing by pressing and holding down
the button within sight of the door
If no cells are installed and cell connectors
are bridged (terminals 18 and 19), check
that dipswitch no.1 is set to OFF.
Obstacle detection
Remove the obstacle by full automatic
opening
Check that no obstacle is cutting across
the cell beam.
Radio frame received from a recognised
transmitter
/
/
Copyright © 2014 Somfy SAS. All rights reserved.
Prog
Tabla de contenido
loading

Tabla de contenido