Application types and operating requirements
Vertical roller awning
Limit switch programming:
Functions available...
Arm awning
Limit switch programming:
Functions available...
Stationary canopy
Limit switch programming:
Functions available...
( )
( )
( )
"1"
( )
"1"
( )
"1"
"S"
"1"
"S"
"1"
"S"
"S"
"S"
Awning "alla romana"
Limit switch programming:
Functions available...
Pergola awning
Limit switch programming:
Functions available...
Warning! – Each automation has its own list of commands that can be memorised
in Mode II; in the case of the present motor the list of commands available is given
in procedure 5.10.2.
5.4.4 - Number of transmitters that can be memorised
You can memorise 30 transmitters (including any radio climate sensors) if these are
all memorised in "Mode I", or you can memorise 30 single commands (keys) if they
are all memorised in "Mode II". The two modes can coexist up to a maximum limit
of 30 memorised units.
• with automatic stop in the upper limit
switch position "0" (with box)
• without containment mechanical con-
straints in the upper limit switch "0"
...in the presence of automatic hooks in the
lower limit switch "1"
...in the presence of manual hooks or bolts
in the lower limit switch "1"
...if it is necessary to reduce the impact
force when closing
• with automatic stop in the upper limit
switch position "0" (with box)
• without containment mechanical con-
straints (square bar or similar)
...to stretch the canvas: "FRT" function
...if it is necessary to reduce the impact
force when closing
• with automatic stop in the upper limit
switch position "0" (with box)
• without containment mechanical con-
straints for the limit switches
...in the presence of automatic hooks in the
lower limit switch "1"
...in the presence of manual hooks or bolts
in the lower limit switch "1"
...if it is necessary to reduce the impact
force when closing
• with automatic stop in the upper limit
switch position "0"
• without containment mechanical con-
straints for the limit switches
...in the presence of manual hooks or bolts
in the lower limit switch "1"
...if it is necessary to reduce the impact
force when closing
• with automatic stop in the two limit
switch positions: upper "0" and lower "1"
• with automatic stop in the lower limit
switch position "1"
• without containment mechanical con-
straints for the limit switches
...if it is necessary reduce the impact force
when closing
Recommended programming
Programming in semiautomatic mode (paragraph 5.7)
Programming in manual mode (paragraph 5.6)
Programming the "FTC" function (paragraph 5.15)
Programming the "FTA" function (paragraph 5.14)
Adjustment of the motor traction force ("RDC" function –
paragraph 5.12)
Programming in semiautomatic mode (paragraph 5.7)
Programming in manual mode (paragraph 5.6)
Programming the "FRT" function (paragraph 5.13)
Adjustment of the motor traction force ("RDC" function –
paragraph 5.12)
Programming in semiautomatic mode (paragraph 5.7)
Programming in manual mode (paragraph 5.6)
Programming the "FTC" function (paragraph 5.15)
Programming the "FTA" function (paragraph 5.14)
Adjustment of the motor traction force ("RDC" function –
paragraph 5.12)
Programming in semiautomatic mode (paragraph 5.7)
Programming in manual mode (paragraph 5.6)
Programming the "FTA" function (paragraph 5.14)
Adjustment of the motor traction force ("RDC" function –
paragraph 5.12)
Programming in automatic mode (paragraph 5.8)
Programming in semiautomatic mode (paragraph 5.7)
Programming in manual mode (paragraph 5.6)
Adjustment of the motor traction force ("RDC" function –
paragraph 5.12)
English – 4