DBI SALA 8560155 Manual De Instrucciones página 6

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 61
Position 4
H.L.L.
57.20 in
145.4 cm
54.50 in
138.4 cm
Step 1:
Follow set-up instructions in section 2.1 of this manual.
Step 2:
The post can be used without the installation of a tie-back as shown in Figure 7 A. Refer to the
"HLL Chart Positions & Ratings", Figure 6 for maximum ratings without the use of a tie-back.
Step 3:
Using the mast with the second and/or third stage erected (Positions 4, 3 & 2) and HLL load
ratings that exceed the load rating shown in the chart, Figure 6, must have tie-backs installed as
shown in Figure 7 B.
Step 4:
Using the davit arm with a HLL requires the third section, (Positions 4 & 3) of the mast to be
erected to install the davit arm sleeve. Refer to the chart to verify tie-back use.
Refer to section 2.2.5 of this manual for Davit Arm set-up.
Step 5:
Install HLL using the carabineer supplied with the HLL assembly to the HLL Anchor Ring provided
on the mast as shown in Figure 7 C. Follow all manufactures instruction carefully when installing a
HLL.
If you require a tie-back, install the tieback using the opposite eye across from the installed HLL on the HLL
Anchor Ring.
Tie-back anchors must be designed and approved by the manufacturer (Capital Safety) and the structure
mounting requirements approved by a qualifi ed engineer. Call Capital Safety to purchase the suitable tie-
back for the application.
The DBI-SALA Portable Fall Arrest Post with HLL Anchor Ring can also be used as an intermediate for a HLL
to spanning across longer distances.
Figure 6 - HLL Chart Positions and Ratings
Horizontal Lifeline (H.L.L.) Positions and Ratings
Position
Position 3
H.L.L.
46.00 in
116.8 cm
43.00 in
109.2 cm
Ultimate Strength
Without Tie-Back
4
3250 Lbs (14.5 kN)
3
4000 Lbs (17.7 kN)
2
4000 Lbs (17.7 kN)
1
5700 Lbs (25.0 kN)
Position 2
41.50 in
105.4 cm
H.L.L.
44.00 in
111.8 cm
6
Position Height
57.25 in. (145.4 cm)
46.00 in. (116.8 cm)
44.00 in. (111.8 cm)
32.75 in. (83.2 cm)
Tie-back Anchorage Connectors
must be approved by Capital
Safety and all tie-back anchor
points must be approved by a
qualified engineer before use.
Position 1
H.L.L.
32.75 in
30.50 in
83.2 cm
77.5 cm