INSTALLATION INSTRUCTIONS
Connecting electric dryers (cont.)
USA only
WARNING
wire should be connected to same color screw. Wire color
indicated on manual is connected to the same color screw
in block. Failure to follow these instructions may result in a
short or overload.
prohibit grounding through the neutral conductor.
Four-Wire Connection for Electric Dryers:
Power Cord
the dryer. Install a UL-listed strain relief into the power cord
through-hole; then thread a UL-listed,
conductor power cord through the
strain relief.
UL-Listed
Cord
Terminal
Block
UL-Listed
Strain Relief
minimum copper conductor and closed loop or forked
terminals with upturned ends.
screw to the center screw of the terminal block. Attach the two
hot leads of the power cord to the outer terminal block screws.
Attach the white neutral wire to the center terminal block
screw. Attach the power cord ground wire to the green ground
screw.
block access cover.
Neutral
Hot
(White)
(Black)
Ground
Screw
Power Cord
Ground Wire
. Reinstall the terminal
Hot
(Red)