Oase Filtral 2500 UVC Instrucciones De Uso página 15

Ocultar thumbs Ver también para Filtral 2500 UVC:
Tabla de contenido
Installation
Set-up the unit
Place the unit in the pond on a horizontal, firm and sludge free ground and ensure that it is completely covered by wa-
ter.
Setting the fountain/water feature (Fig. B, C)
Pull the nozzle tube (11) to the desired length. Undo the clamping screw (10), vertically align the nozzle tube (11) and
fasten the clamping screw (10) hand tight.
Fully open the rotary regulator (18) for the fountain. The rotary regulator (17) for the features or the water course is
also used to control the fountain/water feature. The additional water recirculation via the lateral outlet improves the fil-
tering effect, even if the feature or the water course is not connected.
Start-up
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
Isolate the unit before starting any work.
Secure the unit to prevent unintentional switching on.
Attention! Sensitive electrical components.
Possible consequence: The unit will be destroyed.
Protective measure: Do not connect the unit to a dimmable power supply.
Switching on: Connect the unit to the mains. The unit switches on as soon as the power connection is established.
Switching off: Disconnect the unit from the mains.
The indicator lamp (Fig. A, 21) indicates the ON/OFF status of the UVC lamp.
Malfunctions
Malfunction
The unit is not operating
Delivery or fountain height insufficient or not
consistent,
Cloudy water
UVC lamp does not light up
Unit switches off after a short running period
Cause
No mains voltage
Flow regulator excessively throttled
Nozzle blocked
Excessive pressure losses in the hoses
Intake openings blocked
Filters clogged
Rotor blocked
Pond extremely dirty
Quartz glass tube soiled
Lamp overheated. The temperature switch has
switched off the lamp
UVC lamp defective
UVC lamp is not correctly seated in the socket
Water temperature too high
Remedy
Check mains voltage
Set flow regulator
Unscrew and clean the nozzle insert
Reduce hose length and connecting parts to a
minimum, route hoses as straight as possible
Clean housing
Clean filters
Clean rotor
Remove algae and leaves from the pond,
change the water
Remove UVC clarifying unit and clean the
quartz glass tube
The lamp will automatically switch on again
once cooled down
Replace the UVC lamp
Correctly insert the UVC lamp into the socket
Note maximum water temperature of +35°
- EN -
15
Tabla de contenido
loading

Este manual también es adecuado para:

Filtral 5000 uvc

Tabla de contenido