Ø200mm gas outlet extractor.
Exchanger top lining.
Thermal insulator.
Gas deflector and extractor flange.
6.5.
Cleaning of turbulators and cylinders.
Tie a cable, cord or wire (length> 1500mm) to each cylinder. Lift the cylinder (it is divided into two divisible
parts) until it is released from the positioner, turn it 90 ° and using the element with which we have secured
it, lower the cylinder until it stops. Repeat operation with all the cylinders of the exchanger (14 units).
Unscrew and remove the positioner, taking into account that the element attached to the cylinder continues
to be accessible. Remove the 14 cylinders one by one. Repeat operation with the 14 helicoids and springs.
Pendulums and springs tend to wear, Ecoforest guarantees correct operation and with a minimum loss of
power with wear of up to 50% of their length.
We advise having spare pendulums and springs in your warehouse to replace them and not leave your
customers without service.
Cylinder positioner.
Cylinder of the turbulator (x14).
Top of the turbulator.
Lower part of the turbulator.
Turbulator cylinder (x14) complete.
Once the discharge connection has been disassembled, we shall clean the system parts and the smoke ways.
When the cleaning is over, re-assemble the system.
6.6.
Fireplace.
Clean the walls of the combustion chamber. Also clean the combustion basket. After cleaning the basket,
check its opening and closing from the motors menu (password protected) to ensure correct mechanical
operation and avoid switching on and off.
46
Drawing 18
X14
X14
Drawing 19