AED System Digital Transducer Electronics
7.6 AED9401A basic device specifications
Type
Measuring amplifier
Measuring signal input
Transducer connection:
Strain gage transducer (full bridge)
Transducer connection
Transducer cable length
Bridge excitation voltage
CAN-Bus:
Protocol
Bit rate, max.
Node address
Length of Interface cable
DeviceNet-Bus:
Protocol
Bit rate, max.
Node address
Length of Interface cable
Diagnostics bus:
Protocol
Baud rate
Node address
Length of Interface cable, max.
Control inputs (electrically isolated):
Number
Input voltage range, LOW
Input voltage range, HIGH
Input current, typ., HIGH−level = 24V
1)
Control outputs
Number
Max. output current I
Short circ. cur., typ., U
Short circuit duration
Input current at LOW level
Output voltage HIGH level
Insulation voltage, typ.
Supply:
Supply voltage
Current consumption (with load cell,
RB = 80 Ω and addition. output
current of the control output I
Temperature range: Nom. temperat.
Operating temperature
Storage temperature
Dimensions
Weight, approx.
Degree of protection according to EN
60529 (IEC 529)
Depending on the external supply voltage
1)
2)
Current consumption at 18 V−Supply:
A1780−4.3 en/de/fr/es/it
(electr. isolated):
per output
max
=24V; R
<0.1Ω
b
L
1...4)
out
v 250 mA + IOUT 1...4
at 24 V−Supply:
v 200 mA + IOUT 1...4
at 30 V−Supply:
v 170 mA + IOUT 1...4
IOUT 1...4 = Current of the control outputs
mV/V
Ω
m
V
DC
kbit/s
m
kbit/s
m
kbit/s
m
V
V
mA
Supply from supply voltage
A
A
mA
V
V
DC
V
DC
mA
−10...+40 [+14...+104]
°C [°F]
−20...+60 [−4...+140]
−25...+85 [−13...185]
mm
g
925 (without AD10x)
AED9401A
AD103C
±3, nominal ±2
≥80...4000
6-wire circuit
≤100
5
CANopen
10 ... 1000
1 ... 127
5000 ... 25
DeviceNet
125 ... 500
1 ... 63
1000 ... 100
ASCII/Binary
38.4
0 ... 89
1000
2
0...5
10...30
12
4
0.5
0.8
Unlimited
<2
>15 at I
max
500
18...30
2)
≤250
195 x 100 x 70
IP65
21
HBM