AED System Digital Transducer Electronics
7.4 AED9201B basic device specifications
Type
Measuring amplifier
Measuring signal input
Transducer connection:
Strain gage transducer (full bridge)
Transducer connection
Transducer cable length
Bridge excitation voltage
Interfaces:
Hardware (select. via slide switch)
Interface cable length RS-232
Max. number of bus members
Control inputs (electrically isolated):
Number
Input voltage range, LOW
Input voltage range, HIGH
Input current, typ., HIGH-level = 24 V
Insulation voltage, typ.
1)
Control outputs
(electric. isolated):
Number
Output current at LOW level (IOUT)
Output voltage HIGH level (UOUT)
Output current, max. (IOUT
Insulation voltage, typ.
Diagnostics bus:
Protocol
Baud rate, max.
Node address
Length of Interface cable, max.
Supply:
Supply voltage (DC), nominal
Supply voltage (DC), minimal
Current consumption (without load
cell and Output current)
Temperature range:
Nominal temperature
Operating temperature
Storage temperature
Dimensions
Weight, approx.
Degree of protection
according to EN 60529 (IEC 529)
1)
Depending on the external supply voltage
2)
Current consumption: ≤175 mA +
A1780−4.3 en/de/fr/es/it
mV/V
Ω
m
V
DC
m
m
RS-485
V
V
mA
V
DC
mA
V
mA
)
max
V
DC
kbit/s
m
V
V
mA
°C [°F]
mm
g
Supply voltage U
Bridge resistance R
AED9201B
AD103C
±3, nominal ±2
≥80...4000
6-wire circuit
≤100
RS-232, RS-485 (4 wire)
≤15
≤1000
0...5
10...30
typ. 12
500
Supply from supply voltage
>15 at I
< 500, per output
500
ASCII/Binary
38.4
0 ... 89
1000
18...30
≤175
−10...+40 [+14...+104]
−20...+60 [−4...+140]
−25...+85 [−13...+185]
195 x 100 x 70
925 (without AD10x)
IP65
= 5 V
B
+ ∑ I
1...6
out
B
19
5
90
2
4
<2
max
15
2)
HBM