Pressure Drop Curve Of Heating Coil - Buderus SM80/5 Instrucciones De Mantenimiento Y De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

2
Product Information
2.5

Pressure drop curve of heating coil

Pressure drop curve of bottom heat exchanger
20.00
15.00
10.00
A
5.00
0.00
4.00
6.00
8.00
10.00
12.00 14.00
Fig. 3
Pressure drop curve of bottom heat exchanger
[1]
SM80/5
[2]
SM100/5
Example:
[A]
8 gpm, 2.2feed of head
6
2
1
16.00
18.00
20.00
22.00
24.00
26.00
28.00
gpm
6 720 800 155-18.2T
Pressure drop curve of top heat exchanger
20.00
15.00
10.00
5.00
B
0.00
4.00
6.00
8.00
10.00
12.00 14.00
Fig. 4
Pressure drop curve of top heat exchanger
[1]
SM80/5
[2]
SM100/5
Example:
[B]
8 gpm, 1.4 feed of head
If the two heat exchangers are piped in series, the
pressure drops are cumulative.
If they are operated in parallel, a separate pump is
recommended for each heat exchanger. Otherwise, flow
setters are needed to regulate the flow through the two
heat exchangers.
Ensure that in any case the pumps meet the load.
SM80/5, SM100/5 – 6 720 800 156 (2017/07)
2
1
16.00
18.00
20.00
22.00
24.00
26.00
28.00
gpm
6 720 800 155-19.2T
Tabla de contenido
loading

Este manual también es adecuado para:

Sm100/5

Tabla de contenido