© Panduit Corp. 2013
MAINTENANCE OF POSITIONING DEVICE (PD-600-A)
Adjusting Positioning Device Clamping
1. Release swivel clamp arm and lay CT-600-A tool on table surface.
2. Remove small screw above swivel clamp arm.
3. Rotate the plate above the swivel clamp arm clockwise 1/8 turn to the next threaded hole to
tighten.
4. Re-install small screw above swivel clamp arm.
5. Tighten 2 large screws opposite swivel clamp arm.
6. Position tool in desired orientation and tighten swivel clamp arm.
TROUBLESHOOTING
Problem
Dies stay closed at end of cycle
OPERATING INSTRUCTIONS
Solution
a. Hold actuating lever or foot petal longer to allow the tool
to complete it's cycle
b. Verify correct crimp pocket was used for the wire and
terminal combination. Refer to product packaging or
instructions included with the die
c. Verify the air pressure setting; increase if necessary
Page: 6 of 12
CT-600-A