4.3 Save / change / delete regeneration / maintenance programs
With programmable appliances (fig. 12 below) it is possible to save regen-
eration/ maintenance programs and use them later.
IT is possible to save up to 10 different programs.
4.3.1 Saving regeneration/maintenance cycle
L2
3
1
2
4
(FIG. 12)
In order to save a program, select to activate the function of key book (4). Now use keys 5 and
6 and go to the number of the desired program.
Note: the empty programs will be signalled through the flashing pro-
gram number.
Press Enter (1) to confirm the selected program. The led L1 starts flashing
indicating that the system is currently programming the phase 1.
Set the regeneration parameters as shown in point 4.2.3 .
Once you have programmed the desired phase/phases, press Enter (1) to
save the changes.
PRACTICAL PROGRAMMING DIAGRAM:
To set a program with: an initial regeneration phase at 80°C for 20 minutes
followed by a second regeneration phase at 95°C with core temperature of
65°C and a final maintenance phase at 70°C:
1. Press the key Book
2. Select the number of the program using keys + and - .
3. Press Enter
4. Press the button Regeneration
14
L1
D
7
6
5
8
to access the programming menu.
to confirm the number selected.
9
11
12
10
and set the chamber temperature
13a
13
13b