MADE IN FRANCE
Selection of process and current setting
1- Select MMA mode
Nb. : The TIG 200, the welding current will vary depending on the power supply voltage used:
- on 110V, the current can be set from 10 to 120A.
- on 230V, the current can be set from 10 to 200A.
Adjustable* Hot Start
The 168 up to 160 A. The TIG 200 has a limit of 200 A on 230V, and 120 A on 110V.
1- Press and hold the "Hot Start" button.
2- Select the wanted Hot Start.
Nb. : the display «HI» indicates that the Hot Start is at the maximum setting.
Adjustable Arc Force (TIG 200)
The Arc Force is adjustable between 0 and 100% (within the limit of 200A on 230V, 120A on 110V for the TIG 200).
1- Press and hold the "Arc Force" button
2- Select the required setting
TIG WELDING
Select Start Function
TIG LIFT: Contact start (for the environments sensitive to HF disturbances)
HF TIG : high frequency start without contact
Trigger behaviour
Compatible Torches
TIG 168
•
TIG 200
•
Nb. : The TIG 200 automatically detects the type of torch that is connected. (Suitable for various kinds of
TIG torches: trigger, single command, dual command, dual potentiometer)
2T mode
TIG 168 DC HF/ TIG 200 DC HF FV
1- Select LIFT or HF function.
1- Touch the work-piece with the electrode
2- Press the trigger on the torch
3- Lift the electrode.
•
•
•
1- Press and hold the trigger : pre-gas, up slope, welding
2- Release trigger : down slope, post-gas
Nb. : For dual control torches and dual potentiometer
mand "up / warm current" and potentiometer active, command
«low / cold current» inactive
2- Select the desired current using the potentiometer
EN
com-
17