MSA ALTAIR PRO Manual De Operación página 34

Ocultar thumbs Ver también para ALTAIR PRO:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 97
OPERATION
Calibration – Oxygen
Attention!
The instrument must be calibrated if, during operation, a value different
from 20.8% oxygen in the ambient air is displayed.
In the event of extreme changes in the air pressure or the atmospheric
temperature, false alarms can be created.
Therefore, calibrate the instrument under the conditions of use. The
calibration must be carried out in clean, non-contaminated ambient air.
The ALTAIR PRO is equipped with a feature to allow calibration at pressure
and/or temperature of use.
To enter the calibration mode, make sure you are in fresh, uncontaminated air.
(1) Press the button for 2 seconds.
!
The current oxygen concentration is displayed.
!
The display switches to "
(2) During the "
GAS
"
!
!
After 3 seconds, "
setup.
(3) During the "
20.8% O
The fresh air equalisation must be carried out in clean, non-contami-
nated ambient air. During the process, do not breathe on the sensor.
If no fresh air equalisation is carried out, the instrument returns to
normal operating mode.
!
During the equalisation, the hour glass and "
!
If the equalisation is successful, "
!
If equalisation fails, "
normal operating mode after 5 s.
The current values were not changed.
(4) If calibration fails, check:
!
that the equalisation was carried out in clean ambient air,
that during the equalisation, you did not breathe on the sensor.
!
(5) If necessary, repeat the steps (1) to (4).
"OK" is displayed. Otherwise ("
!
of use.
(6) Conduct self-test to confirm the calibration.
If the self-test is successful, a "
!
34
TEST
GAS
?
" "
" "
CAL
" "
" is displayed.
FAS
" "
FAS
?
" "
" display, press the button to perform a calibration at
.
2
ERR
ALTAIR PRO - Operating Manual
TEST
GAS
?
" "
" "
".
" display, press and hold the button.
?
" is displayed which prompts to do a fresh air
OK
" is displayed
" is displayed and the instrument returns to
ERR
"), the instrument must be taken out
#
" is displayed.
FAS
" are displayed.
MSA
GB
Tabla de contenido

Solución de problemas

loading

Tabla de contenido