OPERATION
High Alarm Setpoint for three seconds, "
(8) To change the high alarm (HI), press the button when "
displays.
HI
!
"
(9) By pressing the button, increase the value for the high alarm, until the
desired value is reached.
!
On obtaining the maximum value, the display jumps back and begins to
count upwards again from the minimum value.
(10) Release the button and wait 3 seconds.
Short Term Exposure Limits "
for three seconds.
(11) To change the STEL setpoint, press the button when the setpoint displays.
ALARM
!
"
(12) By pressing the button, increase the value for the STEL alarm, until the
desired value is reached.
!
On obtaining the maximum value, the display jumps back and begins to
count upwards again from the minimum value.
(13) Release the button and wait 3 seconds.
Time Weighted Average, "
three seconds.
(14) To change the TWA setpoint, press the button when the setpoint displays.
ALARM
!
"
(15) By pressing the button, increase the value for the TWA alarm, until the
desired value is reached.
!
On obtaining the maximum value, the display jumps back and begins to
count upwards again from the minimum value.
(16) Release the button and wait 3 seconds.
16
ALARM
SET
", "
", "
SET
", "
" and "
TWA
SET
", "
" and "
ALTAIR PRO - Operating Manual
HI
" and "
?
" and "
" are displayed.
STL
" displays; then, the STEL setpoint displays
?
" are displayed.
" displays; then, the TWA setpoint displays for
?
" are displayed.
ALARM
" icons turn ON.
HI
ALARM
" and "
MSA
"
GB