Delta 17T Serie Manual Del Propietário página 7

Ocultar thumbs Ver también para 17T Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

4
Installation and Adjustment of the Temperature Knob
Failure to do so may cause injury.
A.
1
A. Adjust temperature limit stop!
Turn on water supplies; LET THE WATER
RUN AT BOTH FULL HOT AND FULL COLD
TO ENSURE THE WATER IS RUNNING
AS HOT/COLD AS POSSIBLE. Place a
thermometer in a plastic tumbler, and hold
the tumbler in the water stream. Place the
temperature knob (1) onto the splines (2),
then rotate the temperature knob counter-
clockwise until you achieve your maximum
desired temperature from the outlet (not
more than 120° or the lower temperature
mandated by your local plumbing code).
B-1.
1
2
Secure the temperature knob using screw (1)
and place cap (2) on knob.
5
Potential scald or thermal shock injury could result due to cross flow if outlet at the
shower is blocked or restricted (e.g., pause control on showerhead). Be sure to point
showerhead away from you when re-starting flow or install inlet check valves on both
supply lines to prevent possible injury.
2
4
3
If max temperature is not achieved before limit
stop (3) on temperature knob (1) meets the
limit stop (4) on the volume control handle.
Remove the temperature control knob (1)
from splines (2). Rotate temperature control
knob (1) clockwise. Place temperature control
knob (1) back onto splines (2) and continue
to rotate counter-clockwise until maximum
desired temperature is achieved.Remove the
temperature knob (1) and replace onto the
splines (2), making sure that the temperature
knob limit stop (3) hits against the volume
handle limit stop (4) as shown.
B-2.
5
2
4
Secure temperature control knob (1) with
screw (2). Hook (3) front of temperature
control cover (4) onto knob (1) before
engaging rear snap (5).
7
Installation
3
1
1
3
68883 Rev. H
4
Tabla de contenido
loading

Tabla de contenido