Options And Accessories - Hatco GLOMAX GM5AH Serie Manual De Instalación Y Operación

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26

OPTIONS AND ACCESSORIES

Non-Adjustable Stands
Aluminum, non-adjustable 406 mm (16") stands are available
as options for the permanent mounting of GM5AH and GM5AHL
Series strip heaters to a countertop.
1. Determine the exact mounting location on the countertop
for the unit. Refer to "Installation Site Requirements" in the
INSTALLATION section of this manual.
2. Prepare the location of each stand mounting flange on the
countertop.
a. Cut out the mounting flange templates provided on this
page. Use the templates for accurate mounting hole and
conduit hole locations.
IMPORTANT NOTE
Make sure the page has not been scaled in size. Measure the
box on this page to check accuracy.
b. Refer to the "Stand Mounting Measurements" table and the
illustration in this section for unit-specific measurements.
c. Verify which stand will have the conduit and LED wire
leads passing through it and the countertop.
d. Carefully measure, locate, and tape each template onto
the countertop at its appropriate position.
e. Drill holes through the approriate "Drill Here" locations on
each template.
3. Feed the conduit and LED wire leads from the unit through
the conduit hole, and position the unit on the countertop.
4. Fasten the stands to the countertop using appropriate
fasteners (not supplied by Hatco). Each mounting flange
has two mounting hole locations.
5. Route the element wire leads and LED wire leads toward
the installation location for the control box. Refer to the
INSTALLATION section of this manual for control box/
control installation.
NOTE: Mounting hole size will be determined by fastener size.
Conduit
Drill Here
Hole Cutout Ø =
26 mm (1")
Stand Mounting Measurements
Model
GM5AH-30
GM5AHL-30
GM5AH-36
GM5AHL-36
GM5AH-42
GM5AHL-42
GM5AH-54
GM5AHL-54
GM5AH-66
GM5AHL-66
GM5AH-78
GM5AHL-78
Mounting
Hole
12
Outside
Inside
Flange (A)
Flange (B)
747 mm
665 mm
(29-3/8")
(26-1/8")
900 mm
818 mm
(35-3/8")
(32-1/4")
1052 mm
970 mm
(41-3/8")
(38-1/8")
1357 mm
1275 mm
(53-3/8")
(50-1/8")
1662 mm
1580 mm
(65-3/8")
(62-1/4")
1967 mm
1885 mm
(77-3/8")
(74-1/4")
Top view of mounting flanges.
Stands removed for clarity.
A
B
Mounting Holes
Conduit Hole
(64 mm [2-1/2"]
on center)
C
This box is
50 mm x 50 mm
when printed
correctly.
Check page scaling if box
is not 50 mm x 50 mm when printed.
Form No. GM5AHCEM-0619
Mounting
Holes (C)
691 mm
(27-1/4")
844 mm
(33-1/4")
996 mm
(39-1/4")
1301 mm
(51-1/4")
1606 mm
(63-1/4")
1911 mm
(75-1/4")
Tabla de contenido