P.c.b. Terminal Blocks
The terminal blocks used on the receiver p.c.b. are quick release lever action type and
consequently do not require a screwdriver to make a termination. The correct method of terminating
is as follows:-
1.Use conductors between 0.85 mm
2.Strip the conductor to a length of 5 mm to 6 mm
3.Press down the relevant terminal block lever with a screwdriver or similar tool.
4.Insert the wire.
5.Release the lever.
Removal of a wire is the reverse procedure
drx 400d.c. Installation Manual
2
and 2.5 mm
2
Page. 5