b. Maximum and Minimum Pan & Tilt Speed Response
Switch 8 ON
Adjust INCH V potentiometer as required
Adjust LENS V potentiometer as required
Switch 5 ON then OFF
Switch 8 OFF
Return the LENS V and INCH V potentiometer to their original position
Check that the pre-set operation is still working
N.B. If the slow speed response is set too slow ,either of the following will occur
If set too fast, hunting can occur whilst searching for a preset position
c. Twilight Threshold Setting
Switch 8 ON
Adjust the LENS V potentiometer as required
Switch 6 ON then OFF
Switch 8 OFF
Return the LENS V potentiometer to its original position
N.B. Factory set, should not need adjusting in normal use
d. Alarm Output Option
Switch 8 ON
Switch 2 OFF then ON
Switch 8 OFF
Switch 2 OFF
N.B. For a new unit this step should be omitted if immediate alarm output activation is required. However, for a previously programmed unit, the following steps
revert the setup from delayed alarm output to immediate alarm operation. Delayed alarm generates A OUT alarm as the preset position is approached
Switch 8 ON
Switch 2 ON then OFF
Switch 8 OFF
e. Active Patrol Always Mode
Switch 8 ON
Switch 3 OFF then ON
Switch 8 OFF
Switch 3 OFF
N.B. For a new unit this step should be omitted if patrol always mode is not used. However ,for a previously programmed unit the following steps revert from Patrol
Always mode = ON to the default setting ( Patrol Always mode = OFF)
drx 400d.c. Installation Manual
I) Control of the pan & tilt may be lost due to motor stall
ii) Pre-set operation may be intermittent or slow
Enters the Programme Mode
Sets the slow speed response
Sets the high speed response
Stores max. and min. speed settings
Exits Programming Mode
Enters the Programme Mode
Sets the twilight threshold
Anti-clockwise = twilight threshold darker
Stores twilight threshold settings
Exits Programming Mode
Enters the Programme Mode
Selects the delayed alarm output
Exits Programming Mode
Returns switch 2 to the default setting
Enters the Programme Mode
Returns the unit to the default setting
(immediate alarm output)
Exits Programming Mode
Enters the Programme Mode
Activates patrol mode
Exits Programming Mode
Returns the unit to the default setting