The specifications of the power supply connection flexible cable must match or be superior to those of the cable with rubber
insulation H07RN-F. Introduce the cable through the cable clamp and secure it firmly. In addition, the supply voltage,
during operation, should not differ from the voltage rating by +/-10%.
The unit is supplied with a cable with the specifications given in Tab. 3; to access the terminal block or replace it,
you need to:
- Remove the terminal-block box on the back of the unit
- Connect the supply cable to the terminal block according to need, following the instructions given on the label located
near the terminal block and in this booklet.
1N AC 220...240 V 50 Hz
TYPE OF VOLTAGE
AC 220...240 V 50 Hz
WIRING DIAGRAM
DRAWING No.
* = 230 V ~ 50/60 Hz
3.
TRANSFORMATION FOR OPERATION WITH ANOTHER TYPE OF GAS
3.1
HOB
Take off the grills, burner lid and burner body.
REPLACING THE PLATE BURNER NOZZLE
Replace the nozzle (Fig. 2 pos. 10) of the burner (size-8 wrench) with one corresponding to the type of gas chosen, following
Tables II Injectors Sect. 3.4.0.
REPLACING THE "BY-PASS" MINIMUM SCREW
- Replace the minimum thermal capacity screw, by-pass (Fig. 2 pos. 2) with the one corresponding to the type of gas chosen,
following Tables II Injectors Sect. 2.5
- The thermal capacity on the minimum position must be approximately 30% of the nominal thermal capacity.
- When you turn the knob fast from the maximum position (
out nor backfire.
CONNECTIONS TO THE ELECTRICITY MAINS
POWER SUPPLY CABLE
MODEL
- 23 -
PE
(Terra)
N
(NP)
L
(R)
1
G4SF6 - G6SF6 - G6SFA6
No. cabels
2
mm
3 x 1,5
) to the minimum position (
yellow-green
blue
brown
Max.
A/f
7,8
) the burner must neither go
GB