Gfci Instructions; Operation - Kärcher HDS 3.5/23-4M Eg Manual De Instrucciones

Ocultar thumbs Ver también para HDS 3.5/23-4M Eg:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Water connection
For connection values refer to technical
specifications
 Attach supply hose (minimum length
24.6 ft/7.5 m, minimum diameter 3/4")
to the water supply set by means of a
hose clamp.
 Connect the supply hose to the water
connection point of the machine and at
the water supply point (for e.g. a tap).
Note: The supply hose and the hose clamp
are not included in the scope of delivery.
Suck in water from vessel
If you want to suck in water from an exter-
nal vessel, the following modification is
necessary:
Figure 6
 Open fill opening for system care.
 Release and remove the cover of the
system care.
 Remove water connection from the fine
filter.
 Unscrew the fine filter from the pump
head.
Figure 7
 Remove the system care reservoir.
 Unscrew the top supply hose to the
swimmer container.
Figure 8
 Connect the top supply hose at pump
head.
 Replug the rinse line of the detergent
dosing valve.
 Connect suction hose (minimum diame-
ter 3/4") with filter (accessory) to the
water connection point.
Max. suck height: 1.6 ft (0.5 m)
Until the pump sucked in water, you should:
 Set the pressure/quantity regulation at
the pump unit to maximum quantity.
 Close the dosing valve for the deter-
gent.
12
Danger
Never suck in water from a drinking water
container. Never suck in liquids which con-
tain solvents like lacquer thinner, petrol, oil
or unfiltered water. The sealings within the
device are not solvent resistant. The spray
mist of solvents is highly inflammable, ex-
plosive and poisonous.
Note: Assembly in reverse order. Ensure
that the solenoid valve cable on the reser-
voir of the system care is not pinched.
Power connection
For connection values, see technical
data and type plate.
The electrical connections must be
done by an electrician according to
NEC and local codes.

GFCI INSTRUCTIONS

 STEP 1: Plug the Ground Fault Circuit
Interrupter (GFCI) into a working outlet.
 STEP 2: Press ''TEST'', then press
''RESET'' to assure proper connection
to power.
Note: The actual appearance of the
GFCI may be different from this illustra-
tion.
Danger
Risk of explosion!
Do not spray flammable liquids.
Caution
Never operate device with empty fuel tank
The fuel pump will otherwise be destroyed.
– 5
EN

Operation

Tabla de contenido
loading

Este manual también es adecuado para:

Hds 3.5/30-4m eaHds 4.0/20-4m eaHds 4.5/22-4m ea

Tabla de contenido