Operation
Illustration on the inside of the front
cover
Insert the mains plug into the socket.
Illustration
Turning on the Appliance
Note: The switch has several switching
stages:
0
Device is switched off
1
Motor 1 switched on
2
Motor 1 and 2 switched on
Always operate the device in stage 2.
ATTENTION
Risk of damage! Always switch the switch-
ing stages quickly in order to prevent dam-
age of the drive motor.
Start suction process.
Note: When vacuuming up fluids, only im-
merse the accessories half way in order to
deliver sufficient air.
Check the fill level display
Note: The red marking on the drain hose
shows the maximum admissible filling lev-
el.
Draining the fluid container by
means of drum pump
Illustration
Secure the disposal hose in the support
when it is not used.
Emptying during vacuuming operation
Connect the disposal hose to the dis-
posal unit.
Plug in the mains plug of the drum
pump.
Start vacuuming operation.
Use the On/Off switch to switch on the
drum pump.
Adjust the delivery rate by means of the
+/- button.
Note: Choose the delivery rate according
to the vacuumed quantity. Prevent the
drum pump from running dry. Do not leave
the drum pump unattended.
Emptying after the vacuuming
operation
Switch off the appliance and remove
the plug from the socket.
Drive the appliance to the disposal site
for the liquid.
Connect the disposal hose to the dis-
posal unit.
Plug in the mains plug of the drum
pump.
Use the On/Off switch to switch on the
drum pump.
Adjust the delivery rate by means of the
+/- button.
Note: Prevent the drum pump from running
dry. Do not leave the drum pump unattend-
ed.
– 4
EN
9