Fireplace Installation
Figure 6
Glass Openings
Partially Reflective Glass
cure and do not protrude past
the flame panel, so as not to
be visible after final assembly.
• Continue to the final assembly
instructions.
240V Installations
Use three conductor, non-metallic
sheath cable with ground wire
(4 wires total) for the incoming
power supply on fireplace inserts.
CAUTION: Use the appropri-
ate wire to meet local and
national electrical codes for
rated power consumption.
• Connect the L1 wire from the
unit to the L1 wire from the
power supply with a wire nut.
• Connect the L2 wire from the
unit to the L2 wire from the
Retaining Bracket
Media Tray
power supply with a wire nut.
• Connect the N wire from the
unit to the neutral wire from
the power supply.
• Connect the G wire from the
unit to the ground wire from
the power supply with a wire
nut or attach the ground-
ing wire to the cover with the
provided grounding screw, by
placing the wire in-between
screw and lock washer and
tighten (Figure 3).
• Ensure that all wires are se-
cure and do not protrude past
the flame panel, so as not to
be visible after final assembly.
• Continue to the final assembly
instructions.
11