16.3 FAULTS CAUSING RESET OR SWITCH OFF (STATE LED IS BLINKING)
- Power stage short circuit
- motor or encoder short circuit, open wires and/or missing signals.
- Internal electronic fault
- Undervoltage (supply voltage is measured and the power stage switches off if the voltage is too low).
- mechanical end not found (>=5m).
- door mechanically blocked.
16.4 FAULTS DECREASING PERFORMANCE OF DOOR
- Motor and/or power stage temperature too high. The software reduces the power of the motor (power
stage). If temperature is nevertheless exceeding a higher limit, power stage is shut down for cooling
down a certain time.
- Low voltage supply like battery drive or low line voltage supply.