13. DESCRIPTION OF LED´S
13.1 LED'S INPUTS
13.2 LED'S OUTPUTS
13.3 DIFFERENT LED'S
Sujeto a cambios sin previo aviso
Name
LED illuminated if
I1
Input 1 is connected to COM
I2
Input 2 is connected to COM
I3
Input 3 is connected to COM
I4
Input 4 is connected to COM
IPD
Input Passenger- Protection Device (Photo cell.....)
Name
LED illuminated if
O1
Output 1 relay is operated
O2
Output 2 relay is operated
O3
Output 3 relay is operated
O4
Output 4 relay is operated
Name
LED illuminated if
POWER
the power supply is switched on
WATCH DOG
the microprocessor does not work
STATUS
Light: during start up and learning
Flashes: if an error is detected
Off: normal operation
REFSW
the door is in Close end area
EXCELLENCE IN COMPONENTS
3411.32.0100 ed.0
GB
Pag.21.78
Subject to change without notice!