11. COMMISSIONING

The door operators supplied directly from the factory are pre-adjusted: it is not necessary to carry out
the door CO (Clear Opening) learning.
The ECO drive at first installation or after switch-off /switch-on will use the first two complete closing /
opening cycles to optimize door CO: STATE LED off

11.1 POWER SUPPLY

- The ECO-drive provides transformers for both different voltage ranges and can supply with 127VAC or
230VAC.
- Select the recommended fuse for the nominal voltage range, see table
Nominal Supply Voltage Range:
Automatic fuse slow (in control panel)
Minimum cable required
- Line in supply is connected to a plug with screw terminals (D1).
11.1.1 Emergency supply
- The battery's supply takes place through the X5 connector.
Pay attention: the battery has to be connected only in case of
absence of the supply indicated on point 11.1.
Sujeto a cambios sin previo aviso
Battery voltage
Min. cable sq. measure
CO optimized.
127VAC
2A
1mm²
PE =
Connect ground wire
N =
Connect neutral wire
120 = Connect 127 VAC phase wire
230 = Connect 230 VAC phase wire
EXCELLENCE IN COMPONENTS
230VAC
1A
0,75mm²
24VDC-4Ah
1,5mm²
Subject to change without notice!