11.1.2 Emergency procedure in automatic mode (specialized technical staff not present):
If mains power is removed, to ensure correct operation of the emergency procedure in automatic mode via the
control panel supplied by the buffer battery, it is necessary to supply the ECO drive with power from a battery
(24 Vdc 4 Ah) via connector X5: the battery power must be supplied immediately after mains power is removed
(the ECO drive must not be switched off ).
The opening of doors for opening I1 (OPENING) will be managed by the control panel. Fig.1 shows the recom-
mended wiring diagram.
NOTE:
If power is removed while the cabin is aligned with the floor and the closure limit switch of the ECO
drive is not activated, the doors can be opened manually, as the ECO drive will leave the motor with-
out power.