EN
– press the button
t
to scroll up the list of parameters and
then
r
to scroll down the list
holding the buttons
r
NOTE:
scrolling movement.
– once the required parameter has been reached, press the
buttons
>
or
<
to modify the value within the permitted range.
The modifications are stored automatically.
3.4
List of parameters
Type
Nr.
Description
Index showing boiler power in kW
PAR
01
0 = 24; 1 = 30
Hydraulic configuration
0 = rapid
1 = storage tank with thermostat or heating only
PAR
02
2 = hot water tank with sensor
3 = two programmer
4=instant with solar power input
Gas Type Configuration
PAR
03
0 = G20; 1 = LPG
Combustion configuration
0 = sealed chamber with combustion control
PAR
04
1 = open chamber with smoke thermostat
2 = Low NOx
PAR
07
Ignition power
PAR
08
External sensor value correction
PAR
10
Boiler Antifreeze Threshold
External Sensor Antifreeze Threshold
PAR
11
-- = Disabled
PAR
12
Heating Curve Incline
PAR
13
Minimum Heating Temperature Adjustment
PAR
14
Maximum Heating Temperature Adjustment
PAR
15
Maximum power heating
PAR
16
Heating Post-Circulation Time
PAR
17
Heating Pump Activation Delay
PAR
18
Re-ignition Delay
Domestic Hot Water Modulation with Flow meter
PAR
19
0 = Disabled
1 = Enabled
PAR
20
Maximum power domestic hot water
PAR
21
Minimum power heating/domestic hot water (premixed)
Domestic hot water preheating enabling
PAR
22
0 = OFF; 1 = ON
External relay 1 function
0 = not used; 1 = remote alarm NO; 2 = remote alarm NC; 3 = zone
PAR
23
valve; 4 = automatic filling; 5 = external request; 6 = recirculation
pump; 7 = zone valve with OT; 8 = relaunch pump
External relay 2 function
0 = not used; 1 = remote alarm NO; 2 = remote alarm NC; 3 = zone
PAR
24
valve; 4 = automatic filling; 5 = external request; 6 = recirculation
pump; 7 = zone valve with OT; 8 = relaunch pump
or
t
increases the speed of the
CONFIGURATION
DOMESTIC HOT WATER - HEATING
When all the parameter modifications have been made, exit the
parameter menu by pressing and holding down the buttons
and
t
for at least 5 seconds until the initial
all at the same time
screen is displayed.
Range
0 .. 1
0 .. 4
0 .. 1
0 .. 2
0 .. 40
-5 .. +5
0 .. +10
-9 .. +5
0 .. 80
20 .. PAR 14
PAR 13 .. 80
0 .. 100
0 .. 99
0 .. 60
0 .. 60
0 .. 1
0 .. 100
0 .. 100
0 .. 1
0 .. 8
0 .. 8
r
U/M
Step
Default
-
1
0 or 1
-
1
0
-
1
0 or 1
-
1
0
%
1
0
°C
1
0
°C
1
3
°C
1
-2
-
1
20
°C
1
20
°C
1
80
%
1
100
seconds
1
3
x 10
seconds
1
0
x 10
Min
1
3
-
1
1
%
1
100
%
1
0
-
1
0
-
-
0
-
-
0
85