12. Defrosting and water draining (Fig. 5)

The Lisbona H125-150 refrigerated cabinet is equipped with a system of off-cycle defrosting.
Electrical defrosting is available on request.
To drain the water produced by defrosting, it is necessary to:
- provide a slightly sloping drainage in the floor (Rif. 11).
- install a drain-trap between the cabinet draining duct and the floor connection;
- hermetically seal the water draining area of the floor.
This procedure prevents the risks of bad smells inside the cabinet, the dispersion of refrigerated air
and possible malfunctioning due to humidity.
N.B.Periodically have a qualified installer check that the hydraulic connections are in a perfect
state.
13. Lighting (Fig. 4)
Lighting inside the cabinet is obtained using fluorescent bulbs (Rif. 8)
The lightswitch can be found on the right of the upper overhead light fixture (Rif. 9).

14. Night blinds - optional - (Fig. 6)

To prevent needless dispersion of the cold and ensure the hygiene of the goods during the night,
optional manual night blinds (Rif. 13 ) are available.
N.B.For cabinets without internal lighting, switch off the lights before closing the cabinet.

15. Replacing lamps (Fig. 4)

To replace the lamp, follow the instructions below:
- Disconnect power to the cabinet.
- Remove the caps (Rif. 6), slip the lamp (Rif. 8) out of the protective casing (Rif. 7) and replace it with
the new one.
- Reinsert the caps, ensuring that the contacts are correctly fitted in the holes provided.
- Reposition the lamp unit in the specific hooks (Rif. 5) until you hear the locking click.
- Restore power supply.

16. Multiplexing of cabinets (Fig. 7)

To connect two or more cabinets in a multiplex, proceed as follows:
- Remove the shoulders if present
- Position the cabinets side by side
- Remove the backs to access the vertical rod holes
- Connect the vertical rods and the brackets using the multiplexing kit supplied (see table)
- Replace the backs
Ref.
8
7
6
5
4
3
2
1
Ref.
5
4
3
2
1
11
MULTIPLEXING KIT
Code
Qty.
Description
04712017
1
TE M8x30 galv. screw
02047000
3
TLD profile alignment plug
02047000
7
Handrail alignment plug D4x80
02940045
1
Ceil. light alignment plug D3x40
04230600
4
M8 Nut
04480112
6
D 8.5 x 24 washer
04711042
2
TCEI M8x60 BR screw
04711065
1
TCEI M8x120 BR screw
HEADPIECE MULTIPLEXING KIT
Code
Qty.
Description
02047000
7
Handrail alignment plug D4x80
04230600
4
M8 nut
04480112
6
D 8.5 x 24 washer
04711042
2
TCEI M8x60 BR screw
04711065
1
TCEI M8x120 BR screw