3-2-2. ADJUSTING THE COLOR TEMPERATURE
The default White Balance data values are set for optimal viewing. The
following instructions are for technicians who have been requested to
customize calibrations for their customers.
1. TV must be ON.
2. Press the following buttons on the Remote Commander
within a second of each other:
MUTING
Factory Mode
Input Source
Aging Mode
Internal Pattern
EDID WP
Site Air Channels
Site Cable Channels
Panel_ID
Color Temp
ADC Calibration
Factory Reset (limited)
Auto Phase
Factory Reset (default)
System
Model Name
Serial Number
Picture Quality
Audio Quality
Panel
Panel Info
3. Using the
button, scroll down to select Color Temp.
KDL-22BX320/22BX321
SEC 3. SERVICE ADJUSTMENTS
MUTING
MENU
<[
TV
]>
<[
Off
]>
<[
Off
]>
Protection
<[
Off
]>
<[
Off
]>
Off
>>
Off
<[
Off
]>
<[
Off
]>
<[
Off
]>
0.07.200D
KDL-22BX320
See rear or side of TV
PQ1.003
AQ4.0002
W_CM22
MT0001.0025.00007V2
[</>]Set [Menu] Exit
Factory Mode
Input Source
Aging Mode
Internal Pattern
EDID WP
Site Air Channels
Site Cable Channels
Panel_ID
Color Temp
.
ADC Calibration
Factory Reset (limited)
Auto Phase
Factory Reset (default)
System
Model Name
Serial Number
Picture Quality
Audio Quality
Panel
Panel Info
to access Color Temp adjustments.
4. Press
<[
TV
]>
<[
Off
]>
<[
Off
]>
Protection
<[
Off
]>
<[
Off
]>
Off
>>
Off
<[
Off
]>
<[
Off
]>
<[
Off
]>
0.07.200D
KDL-22BX320
See rear or side of TV
PQ1.003
AQ4.0002
W_CM22
MT0001.0025.00007V2
[</>]Set [Menu] Exit