Operation
AC-500 Solid State Controls
2
3
8
9
Figure 13
OPERATION
1
NOTE: Operation is restricted to qualified person-
1. Turn on the gas valve (9).
2. Close the oven door.
3. Turn the SELECTOR Switch (1) to the desired
cook position.
The fan will start to turn and the temperature
control will go on.
4. Set THERMOSTAT (7) to the desired tempera-
4
ture.
5
The elements will come on. The OVEN READY
light (6) on the control panel will illuminate.
If in starting, the burner does not ignite within
6
a few seconds, the RESET alarm light (3) will
go on. Press the RESET switch (2) to restart
the burner.
7
The LIGHT OFF OVEN READY light (6) will go
out when the oven has reached temperature.
NOTE: If the oven will not start after several at-
For the HUMIDAIRE control option:
1. When steam is desired, set the STEAM
CYCLE TIMER (8) to the required injection
time.
2. Momentarily press and release the STEAM
CYCLE START button (4). The STEAM indica-
tor (5) will light as water is injected into the
baking compartment.
Shut Down
1. Turn the SELECTOR Switch (1) to OFF.
2. Shut off the gas valve (9).
12
nel.
tempts contact a qualified installer.