Installation
Z_
WARNING
For U.S. models: Risk o1:electrical
shock
•
All U.S.models are designed for a 3-WIRE SYSTEM CONNECTION. The dryer frame is
grounded to the neutral conductor
at the terminal
block. A 4-WIRE SYSTEM CONNECTION
is required for new or remodeled
construction,
mobile homes, or if local codes do not
permit grounding
through
neutral. If you use the 4-wire system, you cannot ground the
dryer frame to the neutral conductor
at the terminal
block.
•
Remove the terminal
block cover plate. Insert the power cord with a UL-listed strain relief
through the hole provided
in the cabinet near the terminal
block.
•
A strain relief must be used. Do not loosen the nuts already installed on the terminal
block. Be sure they are tight. Use a 3/8" (lcm) deep well socket.
9_
To ensure that the dryer provides
optimal dr?ing performance,
it must
be level. To level the dryer, follow the
lettered steps below:
A.
Using a leveller
(A), check if the
dryer is level side to side and then
front to back.
13. If the dryer is not level, adjust the
leveling feet (B) on the bottom of the
dryer until the dryer is level side to
side and back to front.
Turning the feet clockwise
retracts
the feet. Turning the feet clockwise
loosens and extends them.
J
24
English